Use Caution if using Generators, Heaters Due to Winter Storm Power Outages

Posted by on Dec 15, 2010

With the first serious winter storm of the season expected to hit Kentucky tonight, the Kentucky Public Service Commission (PSC) is urging residents to exercise caution in the event their electric service is interrupted.
The National Weather Service (NWS) is forecasting that a mixture of snow, sleet and freezing rain will move into Kentucky later today. Some areas of Kentucky might see ice accumulations of as much as half an inch, forecasters say.
That much ice can break weak tree limbs and bring them down on power lines. Some scattered power outages are possible, the PSC said.
Customers who lose power should follow proper safety precautions if they use portable generators or heating appliances, PSC Chairman David Armstrong said.
“As we learned during the record-breaking ice storm in 2009, improper use of portable generators and heaters can be extremely dangerous,” Armstrong said. “Many Kentuckians lost their lives, and many more were hospitalized, as the result of being poisoned by carbon monoxide emitted by portable generators that were not used correctly.”

To avoid carbon monoxide poisoning:

  • Generators should only be operated outside in well-ventilated areas.
  • Do not operate generators in a garage, basement or breezeway.
  • Do not operate generators near windows, doors or in other areas where exhaust fumes could be drawn into a home or other occupied structure.
  • Do not use charcoal grills, gas grills or other open-flame devices indoors for heating or cooking. If using a fireplace or wood stove for heat, make sure that it is properly vented and working properly.
  • Use only portable heaters approved for indoor use and use them in only accordance with manufacturer instructions.

Use of portable heating devices also poses a fire hazard. Avoid heaters that don’t have safety devices such as automatic shut-offs in the event of overheating or tipping over. Keep all flammable materials at least three feet away from portable heaters.
The PSC also is reminding electric customers who use a portable generator of electric safety guidelines that will protect them and those working to restore power. Keys to safe operation of a generator installation include:

  • Make sure a generator like the trusted predator 4000 generator is properly sized for the load you will place on it. Remember that starting an electric motor, such as a refrigerator compressor, requires more electricity than the amount needed to keep it running. DO NOT OVERLOAD YOUR GENERATOR.
  • Use only three-prong, grounded extension cords, properly rated for the load, to connect appliances to generators.
  • DO NOT ATTEMPT TO FEED POWER INTO YOUR HOME BY ADAPTING AN EXTENSION CORD TO CONNECT A GENERATOR TO A WALL OUTLET. THIS CAN CAUSE A FIRE.
  • DO NOT CONNECT A GENERATOR TO INSIDE WIRING IN ANY WAY UNLESS YOUR HOME OR BUSINESS IS EQUIPPED WITH A TRANSFER SWITCH THAT PREVENTS POWER FROM FLOWING BACK INTO (BACKFEEDING) THE WIRES THAT SUPPLY YOUR ELECTRICITY.

Backfeeding poses a severe danger to workers attempting to restore electrical service. They can be severely injured or killed by power flowing back into lines which they assume are not carrying electricity. Also, if the line to your home or business becomes grounded, backfeeding can permanently damage your generator.
Customers who lose power should contact their utility company immediately. Most utilities in Kentucky have systems that use customer reports to help identify the location of the problem and determine what repairs are needed.
“It is important that every customer call to report an outage,” Armstrong said. “But repeated calls simply tie up the utility’s phone system. Call at once, but call only once.”
Customers who lose power also should check electric connections and meters for damage. Damaged connections or meters must be repaired before power can be restored to a home or business.
Falling or sagging power lines may have damaged the connections between the utility company’s overhead line and a customer’s electric system. The connections are usually in the form of a masthead – a conduit connected to the service line – or, in older homes, an eyebolt which holds the line in place and an insulated line leading to the meter. In some cases, the meter or meter base may also be damaged.
Once power is restored, damaged connections or meters could pose an electrical or fire hazard if not repaired or if repaired improperly.
“It is critical that damaged connections be repaired by a qualified professional and inspected before power is restored,” PSC Chairman Armstrong said. “In past outages, fires and severe damage have been caused by damaged or improperly repaired service connections.”
Repairing a service connection or meter base is the responsibility of the individual customer. The meter base is the square or rectangular box on which the meter itself is mounted. It belongs to the property owner. The meter itself – the circular, glass-enclosed portion that attaches to the meter base – is the property of the utility company.
Customers with damaged connections or meters should take the following steps:

  • Notify the utility company that the service connection, meter base and/or meter is damaged. The utility can then make sure that the line is not energized until repairs are completed.
  • In the event that only the meter itself is damaged, contact the utility to have it repaired or replaced and your service restored.
  • Contact an electrician to repair the meter base or service connection. The repair work can be done prior to power being restored in an area, thus eliminating any additional delays.
  • The electrician will obtain the proper meter base from the utility. Some utilities impose no charge for the meter base, but the customer will bear the installation cost.
  • Have the repairs inspected by a state-certified inspector working for your local government. The electrician should be able to help arrange the inspection.
  • Notify the utility when the repairs are complete and have been approved. A utility technician will install a new meter and restore the power.
  • Keep all repair records and contact your property insurer.

Residents SHOULD NOT attempt to remove any branches, limbs or trees that have fallen across service connections or other utility lines. Notify the utility to arrange for the debris to be removed.
“We certainly hope that Kentucky will get through this storm without any disruptions in utility service,” Armstrong said. “But if disruptions occur, we want those affected to stay safe while they wait for power to be restored.”
The PSC is an independent agency attached for administrative purposes to the Energy and Environment Cabinet. It regulates more than 1,500 gas, water, sewer, electric and telecommunication utilities operating in Kentucky and has approximately 100 employees.